Journal Article

·2010

Disturbance observer based control of three phase UPS inverter

Sinan Unan , Haluk Görgün YTU , Faruk Bakan YTU

Abstract

In this paper control of three phase UPS inverter with cascaded PI controller and load current estimation via disturbance observer are presented. Pure sinusoidal waveform with specified amplitude and frequency is required for UPS inverter under variety of loads. Load current acts as disturbance on the plant. To increase the disturbance rejection of the plant, the load current is adopted as feed forward loop to the voltage controller. Disturbance observer method is relatively simple method in comparison with Luenberger observer. The proposed algorithms are successfully presented with simulations and verified by experimentally.

Keywords

Control theory (sociology) Inverter Disturbance (geology) Waveform Controller (irrigation) Observer (physics) Voltage Amplitude Computer science Engineering Control (management) Physics

Subject Areas

Microgrid Control and Optimization ·Control and Systems Engineering ·Physical Sciences
Advanced DC-DC Converters ·Electrical and Electronic Engineering ·Physical Sciences
Power Systems and Renewable Energy ·Energy Engineering and Power Technology ·Physical Sciences

Citations by Year

OpenAlex SDG Match

SDGs auto-classified by OpenAlex (score ≥ 0.4 shown).

Affordable and clean energy 76%