Journal Article

·2020 OPEN ACCESS

Оптимизация уравнения для вычисления коэффициента заполнения при проектировании сборок Хальбаха

Furkan BALCI YTU , А. Bingolbali YTU , N. Doğan YTU , M. Irfan

Письма в журнал технической физики

Abstract

Selection (spatial in-homogenous) and excitation (spatially homogenous) fields are designed with Halbach magnets for magnetic particle imaging (MPI) and magnetic resonance imaging (MRI). Permanent magnet parameters (length and remanent flux density) and geometrical parameters (fill factor (FF), number of magnets, and system radius) are key factors for Halbach applications. The effect of fill factor ratio at magnetic flux density was investigated with 4 and 8 cylindrical magnets. A new mathematical expression was developed for accurate placement of the magnets even at 100% filling ratio (FF=1). Numerical simulations were conducted for the proposed model and magnetic flux density of 4 magnets system was 17% more accurate as compared to the model in the literature.

Keywords

Magnet Magnetic flux Excitation RADIUS Flux (metallurgy) Remanence Physics Magnetic field Nuclear magnetic resonance Halbach array Materials science Magnetization Computer science

Subject Areas

Characterization and Applications of Magnetic Nanoparticles ·Biomedical Engineering ·Physical Sciences
Magnetic Properties and Synthesis of Ferrites ·Materials Chemistry ·Physical Sciences
Magnetic Properties and Applications ·Electronic, Optical and Magnetic Materials ·Physical Sciences

OpenAlex SDG Match

SDGs auto-classified by OpenAlex (score ≥ 0.4 shown).

Sustainable cities and communities 44%